Buildingsync Measures Gem

This repository contains measures used in the BuildingSync to OpenStudio Simulator (BOSS) workflow.

Installation

Add this line to your application's Gemfile:

gem 'buildingsync-measures'

And then execute:

$ bundle

Or install it yourself as:

$ gem install 'buildingsync-measures'

Usage

Measures are packaged as OpenStudio extension measures under lib/measures and can be registered from the repository root:

openstudio --verbose measure -r ./lib/measures

Measure inventory

General model measures:

  • disable_sizing_runs - disables sizing-period simulation and keeps weather-file run periods enabled.
  • modify_envelope_insulation - adjusts exterior wall, roof, and floor construction insulation to target R-values or U-values.
  • modify_schedules - creates or replaces OpenStudio schedules from BuildingSync-aligned schedule payloads.
  • set_infiltration_by_ach - updates existing infiltration objects to a natural ACH value, with optional ACH50 conversion.

HVAC configuration is split into 22 independent measures:

  • 17 neutral topology measures each support operation = create and operation = replace.
  • modify_existing_air_loop_controls
  • modify_existing_hvac_equipment_efficiencies
  • modify_existing_plant_equipment
  • modify_existing_heat_recovery
  • modify_existing_plant_loop_temperatures

See the HVAC mapping and migration guide for the full BuildingSync predicates, legacy modify_hvac mappings, workflow responsibilities, and known limitations. The monolithic modify_hvac measure is retained temporarily for backward compatibility but is deprecated for new workflows.

BuildingSync HVAC mapping overview

For L100 / family-level data, PrincipalHVACSystemType locates a system family. For L200 / detailed data, use the linked sources, deliveries, plants, and ventilation records to identify the actual configuration. These are intended audit uses, not schema-enforced field restrictions; a principal label alone does not establish a detailed match.

This is a short overview, not the complete selection contract. Field names and conditions are abbreviated below. Use the full four-column mapping for exact paths/values, required ID references, guards, zone grouping, and call arguments. The baseline is BuildingSync 2.7.0 and openstudio-standards 0.8.2; the measures do not parse BuildingSync themselves.

Mapping gaps identify schema or measure enhancements needed for an exact match; the listed measures still exist and produce the stated output. Not mappeable in this gem identifies configurations with no current matching gem measure, not a limitation of BuildingSync or OpenStudio. Missing/unknown data is a separate issue.

HVAC type / configuration BuildingSync configuration — summary only Measure / fixed output Notes / development gaps
Packaged Terminal Air Conditioner ZoneEquipment; PTAC DX source, electric resistance, air-cooled condenser hvac_ptac: DX cooling + electric heat, one unit/zone No gas/hot-water PTAC variant.
Four Pipe Fan Coil Unit FanCoilType = "Fan coil 4 pipe"; hot-water boiler + chilled-water plant hvac_four_pipe_fan_coil: four-pipe units, gas boiler, water-cooled electric chiller Exact plant IDs/grouping matter; no two-pipe changeover.
Packaged Terminal Heat Pump ZoneEquipment; packaged-terminal HP + PTHP DX source, electric backup, air-cooled condenser hvac_pthp: DX heating/cooling + electric backup, one unit/zone Backup is electric, not gas.
Packaged Rooftop Air Conditioner Single-zone central air, CAV no-reheat terminal; packaged DX + gas furnace hvac_packaged_rooftop_ac: one packaged AC loop/zone Gas heat + electric supplemental heat.
Packaged Rooftop Heat Pump Single-zone central air, CAV no-reheat terminal; packaged-unitary HP + electric backup hvac_packaged_rooftop_heat_pump: one packaged HP loop/zone No multizone packaged-HP option.
Packaged Rooftop VAV with Hot Water Reheat Multizone central air; non-fan-powered VAV, packaged DX, shared hot-water central heat/reheat hvac_packaged_rooftop_vav_hw_reheat: packaged VAV + gas boiler Central heat/reheat must use the same boiler.
Packaged Rooftop VAV with Electric Reheat Multizone central air; fan-powered VAV, packaged DX, electric central heat/reheat hvac_packaged_rooftop_vav_electric_reheat: parallel fan-powered electric-reheat boxes Mapping gap: distinguish parallel/series boxes in the schema; add series support to the measure if needed.
VAV with Hot Water Reheat Multizone central air; non-fan-powered VAV, chilled water, shared hot-water central heat/reheat hvac_vav_hw_reheat: VAV + gas boiler/water-cooled electric chiller Central heat/reheat must use the same boiler.
VAV with Electric Reheat Multizone central air; fan-powered VAV, chilled water, electric central heat/reheat hvac_vav_electric_reheat: parallel fan-powered electric-reheat boxes Mapping gap: distinguish parallel/series boxes in the schema; add series support to the measure if needed.
Warm Air Furnace Single-zone central air; warm-air gas furnace + explicit NoCooling hvac_warm_air_furnace: gas heating-only loop/zone No split cooling or alternative-fuel option.
Ventilation Only VentilationType = "Supply only"; stand-alone, separately linked deliveries with NoHeating + NoCooling hvac_ventilation_only: unconditioned direct-to-zone supply loop Run after compatible zone equipment; no coils/recovery/exhaust-only service.
Dedicated Outdoor Air System VentilationType = "Dedicated outdoor air system"; stand-alone, separately linked deliveries with NoHeating + NoCooling hvac_doas: unconditioned direct-to-zone DOAS The DOAS label alone does not imply unconditioned air; run after zone equipment.
Water Loop Heat Pump Zone heat-pump/DX sources linked to a water-cooled condenser record hvac_water_loop_heat_pump: water-to-air HPs, gas boiler + evaporative fluid cooler Mapping gap: add explicit terminal/shared-loop/fluid-cooler distinctions and corresponding measure options.
Ground Source Heat Pump Zone heat-pump/DX sources linked to GroundSource; open-/closed-loop type hvac_ground_source_heat_pump: temperature-source loop approximation Mapping gap: implement physical open-/closed-loop options or explicitly expose/document the approximation mode.
VRF Terminal Unit FanCoilType = "VRF terminal units"; VRF DX, linked heating HP, air-cooled condenser hvac_vrf: one outdoor unit/source group, zone terminals Multi-split is not the VRF terminal enum; preserve outdoor-unit identity.
Chilled Beam ConvectionType = "Chilled beam"; hot/chilled-water sources hvac_chilled_beam: active four-pipe beams + conditioned primary air Mapping gap: add active/passive and pipe-arrangement selectors/options. Do not append separate DOAS.
Hydronic radiant floor / ceiling RadiantType = "Radiant floor or ceiling"; hot/chilled-water sources hvac_radiant: hydronic heating/cooling floors Mapping gap: distinguish floor/ceiling in the schema and add surface-selection options. No named radiant principal enum.
Split AC / conventional mini-split HP; two-pipe fan coil; baseboard/radiator Detailed DX, fan-coil, convection, or radiant subtype not mappeable in this gem No matching topology builder; do not substitute packaged equipment or four-pipe/radiant-floor systems.
Other central-air / plant variants Conditioned multizone CAV, VAV-no-reheat, dual ducts, steam/district plants, absorption or air-cooled chillers not mappeable in this gem See the full table for exact unsupported configurations, including terminal/reheat combinations.
Conditioned DOAS; HRV/ERV; exhaust; humidity control; natural ventilation Detailed OtherHVACSystems type and linked conditioning sources not mappeable in this gem for equipment creation Existing heat-recovery equipment can be modified; modifiers do not create it or add DOAS coils.
Explicitly no HVAC Explicit NoHeating, NoCooling, no delivery mechanism, linked ventilation None No measure call Missing HVAC data is not an explicit no-system declaration.
Other / Unknown Principal label alone supplies no configuration not mappeable in this gem from the label alone Missing configuration data, not proof that a measure is unavailable; evaluate detailed records.

For multiple measures, build the matching zone equipment first and unconditioned DOAS/supply ventilation last. Keep each call's exact zone set; central-air systems cannot share zones with a separate DOAS. Hydronic mappings have a conservative single-plant-generating-call constraint because the wrappers cannot bind arbitrary plant IDs. Consult the complete mapping and grouping requirements before assembling a workflow; an unresolved gap must not silently become a default subtype. Apply validated property modifiers afterward.

Testing

Run gem-level tests with:

bundle exec rake spec

Run the focused independent-HVAC integration suite with:

bundle exec rspec spec/tests/independent_hvac_measures_spec.rb

Run individual non-HVAC measure tests directly with OpenStudio available:

bundle exec ruby lib/measures/disable_sizing_runs/tests/disable_sizing_runs_test.rb
bundle exec ruby lib/measures/modify_envelope_insulation/tests/modify_envelope_insulation_test.rb
bundle exec ruby lib/measures/modify_schedules/tests/modify_schedules_test.rb
bundle exec ruby lib/measures/set_infiltration_by_ach/tests/set_infiltration_by_ach_test.rb

All 22 independent HVAC measures also have local Minitest suites and checked-in OSM inputs. For example, see the DOAS tests and their model.

Run all independent HVAC unit tests, or one measure:

bundle exec rake test_hvac
bundle exec ruby lib/measures/hvac_doas/tests/hvac_doas_test.rb

Each measure invocation saves input/output models and runner diagnostics under that measure's test output directory, including intentional failures. Assertions inspect the saved-and-reloaded output rather than just checking the runner status. See Per-measure unit tests in the HVAC migration guide for scenarios, artifact locations, fixture maintenance, and test selection.

The legacy modify_hvac direct test remains unchanged with the deprecated measure during its compatibility window. The gem-level RSpec suite continues to provide cross-measure integration coverage; rake spec and the default Rake task retain their existing behavior.

Migration Status

All 17 exact HVAC topologies now have one independent operation-aware measure, and all five focused modifiers are implemented. The suite is validated against OpenStudio 3.10 and openstudio-standards 0.8.2. Small local duplication is intentional: each measure is independently packaged and does not invoke another measure or depend on a shared production dispatcher.

The remaining migration step is to remove deprecated modify_hvac after consumers switch to the exact-type measures. That removal and the associated version change will be handled as a breaking pre-1.0 release. The BuildingSync mapping gaps above track schema/measure enhancements separately from this measure-splitting migration.

TODO

  • Remove measures from OpenStudio-Measures to standardize on this location
  • Update measures to code standards
  • Remove deprecated modify_hvac after the consumer migration window
  • Validate release candidates against representative multi-zone models and OSW workflows
  • Review and fill out the gemspec file with author and gem description

Releasing

  • Update change log
  • Update version in /lib/openstudio/buildingsync-measures/version.rb
  • Merge down to master
  • Release via github
  • run rake release from master