> @yoe [91cb697](https://github.com/OpenLightingProject/ola/commit/91cb697912664d58317d001f1e7998ac556c9de6) should fix those test on Big Endian architecture, would you mind testing it somehow as I've only dummied it up by reversing stuff on an LE machine. @brucelowekamp care to take a look at it for any Python howlers I've introduced?
I don't know of any python concerns, but I do have to ask if this isn't a protocol error? It's sent out on the socket, so if you were to use the API across two endian machines, it wouldn't work? Looks like both the Python and C++ do the same thing, but still....
There won't/shouldn't be any inter-machine comms and hence any multi-endian issues. Whereas if we do fix it, then if someone runs an unfixed client against a fixed server, it won't work. Although given this is only on BE machines, I guess it's a fairly low risk. It will definitely be a breaking change though, so I'm not sure I'm personally convinced of the benefit apart from hypothetically. I guess we should at least flag the lines of code with a TODO and possibly consider making the change for 0.11.0 or similar.
(10:52:23) wouter: PeterNewman4: your patches don't seem to resolve the issue
(10:52:31) wouter: that is, it kind of works, but things seem to hang
(10:52:58) wouter: and I also get a line saying "WARNING:root:Protocol mismatch: 3 != 1" when I run python/ola/RDMTest.py
Having had a better look, that code is in our codebase:
Given it's the RDM ones, presumably it's of course going to be because they have responses too and I haven't mangled those responses on the way back out, so it can't read them on BE architectures/thinks they're corrupt!
If it helps: I do have a Big Endian machine here (iBook G4) that I can use to test stuff. Of course, qemu might do as well but I wanted to mention it anyways. Remote access can be arranged but beware, it's a slow machine
Activity
peternewman commentedon Nov 12, 2022
My original reply:
I'd be tempted to agree with you @brucelowekamp and I did consider fixing it. However due to the limitations mentioned here:
http://docs.openlighting.org/ola/doc/latest/rpc_system.html#rpc_OLA_RPC
There won't/shouldn't be any inter-machine comms and hence any multi-endian issues. Whereas if we do fix it, then if someone runs an unfixed client against a fixed server, it won't work. Although given this is only on BE machines, I guess it's a fairly low risk. It will definitely be a breaking change though, so I'm not sure I'm personally convinced of the benefit apart from hypothetically. I guess we should at least flag the lines of code with a TODO and possibly consider making the change for 0.11.0 or similar.
Unfortunately @yoe found it didn't entirely work:
Having had a better look, that code is in our codebase:
ola/python/ola/rpc/StreamRpcChannel.py
Lines 246 to 250 in d101097
Given it's the RDM ones, presumably it's of course going to be because they have responses too and I haven't mangled those responses on the way back out, so it can't read them on BE architectures/thinks they're corrupt!
Originally posted by @peternewman in #1687 (comment)
peternewman commentedon Nov 12, 2022
In fact this would need to be for 1.0.0 given "MAJOR version when you make incompatible API changes".
[-]RPC API Has fixed endianness[/-][+]RPC API Has host endianness[/+]kripton commentedon Feb 15, 2023
If it helps: I do have a Big Endian machine here (iBook G4) that I can use to test stuff. Of course, qemu might do as well but I wanted to mention it anyways. Remote access can be arranged but beware, it's a slow machine
DaAwesomeP commentedon Feb 15, 2023
I'm going to attempt s390x in QEMU in the new GitHub Actions CI. For Python projects I have used cibuildwheel which uses QEMU for s390x very reliably.