Skip to content

Floating-copper cleanup silently deletes an entire authored <copperpour> (no copper, no KiCad zone, and the isolated-pour warning disappears) #5604

Open

Description

@bhatipoglu

Summary

If an authored <copperpour> has no same-net copper on its own layer, Board_doInitialPcbCopperPourCleanup deletes every fragment of it (db.pcb_copper_pour.delete(pourId)) and emits no copper-pour diagnostic. Two examples: an inner1 plane, or a bottom pour whose net has only top-layer SMT pads. The net still has same-net pads elsewhere, so the floating-copper check treats the pour as removable. Nets with no anchors at all keep their pours (find-floating-copper.ts:344).

After the cleanup, the Circuit JSON has no pcb_copper_pour and the KiCad export has no (zone …). The existing pcb_copper_pour_isolated_warning never appears either, because the pour is deleted before the island check can see it. The user believes they have a ground plane and silently gets none.

Repro

// tests/repros/repro5068-authored-pour-removed-silently.test.tsx
import { expect, test } from "bun:test"
import { getTestFixture } from "tests/fixtures/get-test-fixture"

test.each([
  { layers: 4, layer: "inner1" },
  { layers: 2, layer: "bottom" },
] as const)(
  "unseeded authored $layer pour is not removed silently",
  async ({ layers, layer }) => {
    const { circuit } = getTestFixture()
    circuit.add(
      <board width="20mm" height="10mm" layers={layers}>
        <resistor
          name="R1"
          resistance="10k"
          footprint="0603"
          connections={{ pin1: "net.GND", pin2: "net.GND" }}
        />
        <copperpour connectsTo="net.GND" layer={layer} />
      </board>,
    )
    await circuit.renderUntilSettled()
    const json = circuit.getCircuitJson()
    const pours = json.filter((e) => e.type === "pcb_copper_pour")
    const warnings = json.filter(
      (e) => e.type === "pcb_copper_pour_isolated_warning",
    )
    // Today: pours.length === 0 and warnings.length === 0.
    expect(pours.length > 0 || warnings.length > 0).toBe(true)
  },
)

On main (v0.0.2399, 0ce5c61) both cases fail: 0 pass, 2 fail.

Expected

At least one diagnostic for an authored pour whose islands are all removed. For example, keep emitting pcb_copper_pour_isolated_warning with the pour id, layer and net, or add a pcb_copper_pour_removed_warning. Optionally, keep the authored outline so the KiCad export still contains the zone definition. KiCad's own island removal keeps the zone and only empties the fill.

Actual

  • pcb_copper_pour: 0
  • copper-pour warnings: none (the only warning is the unrelated schematic_missing_sheet_warning)
  • KiCad .kicad_pcb: 0 zones

Evidence

  • When Board.prototype.doInitialPcbCopperPourCleanup is stubbed to a no-op, both cases pass. Each gives 1 pcb_copper_pour, 1 KiCad zone, and:
    Copper pour for GND has an isolated island on inner1 near (0.00 mm, 0.00 mm) with no physical connection to a same-net pad or via
    (the same message for bottom). The information exists; the cleanup removes it first.
  • The cleanup was introduced in Remove electrically isolated copper pours after via stitching #3699. Preserve authored copper during cleanup #4687 ("Preserve authored copper during cleanup") was closed without merging. lib/components/normal-components/Board/Board_doInitialPcbCopperPourCleanup.ts is unchanged on main.

Versions

  • @tscircuit/core v0.0.2399 (0ce5c61, current main), Bun 1.3.14, circuit-json-to-kicad 0.0.272 (core dev dependency), tested in this repo's own test setup.
  • Also seen downstream with tscircuit 0.0.3192 / core 0.0.2385 and tscircuit 0.0.3208 / core 0.0.2399.

Activity

  1. 0hmX commented on Nov 19, 2026

    @0hmX
    Contributor

    I don't think this is a bug. Removing unconnected copper pours is standard behavior. Here, nothing connects the GND pads to the inner1/bottom pour, so cleanup flags it as dangling copper and removes it. That's expected: any copper pour assigned to a net that isn't physically connected to that net should be removed.

    To keep the pour, connect it explicitly. For example, add a via or a trace with a custom pcbPath down to the pour's layer, or use autorouter="fanout", which treats the pour as a plane and adds the vias for you.

    Closing this as working as intended.

  2. bhatipoglu commented on Nov 20, 2026

    @bhatipoglu
    Author

    Thanks, that makes sense. Removing a pour that has no physical connection to its net is the right behaviour, and a via, a pcbPath trace or autorouter="fanout" fixes the board.

    What I'd still like to address is that the removal is silent. When cleanup removes an entire authored <copperpour>, Circuit JSON has no pour and no warning, and the KiCad export has no zone. Nothing tells the user why their plane is missing. #5736 keeps the removal exactly as it is. It only emits one pcb_copper_pour_isolated_warning for the removed pour, with the net, the layer and the same fixes you suggested here.

    If you'd rather not add a warning either, I'm happy to close #5736 along with this issue.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment